Search
Now showing items 1-10 of 39
Classification of narcotics in solid mixtures using principal component analysis and Raman spectroscopy
(ASTM International, 2002-03-01)
Eighty-five solid samples consisting of illegal narcotics diluted with several different materials were analyzed by near-infrared (785 nm excitation) Raman spectroscopy. Principal Component Analysis (PCA) was employed to ...
Low Temperature Fluorescence Studies of Crude Petroleum Oils
(2011)
We have studied the low-temperature (133-298 K) fluorescence emission of crude petroleum oils using a combination of steady-state and time-resolved measurements. This was done, first, to see if we could generate linear ...
Prediction of Cell Culture Media Performance Using Fluorescence Spectroscopy
(2010)
Cell culture media used in industrial mammalian cell culture are complex aqueous solutions that are inherently difficult to analyze comprehensively. The analysis of media quality and variance is of utmost importance in ...
A rapid fluorescence based method for the quantitative analysis of cell culture media photo-degradation
(Elsevier (Science Direct), 2013-11-21)
Cell culture media are very complex chemical mixtures that are one of the most important aspects in biopharmaceutical manufacturing. The complex composition of many media leads to materials that are inherently unstable and ...
Kernel principal component analysis residual diagnosis (KPCARD): an automated method to remove cosmic ray artefacts in Raman spectra.
(2016)
A new, fully automated, rapid method, referred to as kernel principal component analysis residual diagnosis (KPCARD), is proposed for removing cosmic ray artifacts (CRAs) in Raman spectra, and in particular for large Raman ...
Monitoring local unfolding of bovine serum albumin during denaturation using steady-state and time-resolved fluorescence spectroscopy
(Springer, 2010-03)
In a previous report (J. Fluoresc. 16, 153, 2006) we studied the chaotropiclly induced denaturation of Bovine Serum Albumin (BSA) using the fluorescence decay kinetics at different stages in the denaturation of BSA by ...
Analysis of hydrocarbon bearing fluid inclusions HCFI) using time-resolved fluorescence spectroscopy
(Society of Photo-optical Instrumentation Engineers, 2005)
Hydrocarbon-bearing fluid inclusions (HCFI) are microscopic cavities within rocks that are filled with petroleum oil, the
composition of which may not have changed since the trapping event. Thus, the composition of that ...
Influence of chemical composition on the fluorescence lifetimes of crude petroleum oils
(Society of Photo-optical Instrumentation Engineers, 2003)
Fluorescence based methods are increasingly being used for the analysis of crude oils because they offer high speed, low
cost, non-contact, and non-destructive testing options. The fluorescence of crude oils is due to the ...
Low-content quantification in powders using Raman spectroscopy: a facile chemometric approach to sub 0.1% limits of detection.
(American Chemical Society, 2015-02-23)
A robust and accurate analytical methodology for low-content (<0.1%) quantification in the
solid-state using Raman spectroscopy, sub-sampling, and chemometrics was demonstrated using
a piracetam–proline model. The method ...
Time-domain measurement of fluorescence lifetime variation with pH
(Society of Photo-optical Instrumentation Engineers, 2001)
Advances in the design and miniaturization of the lasers and electronics required for Time Correlated Single Photon Counting (TCSPC) measurement of fluorescence lifetime have simplified the use of the time domain method. ...










